Back to Torque

Shaft Driven Transformer
Coupled Torque Sensor
Model T261

  • Non-contact measurement of torque
  • High stiffness and low inertia
  • On-board shunt calibration circuit
  • Internal zero velocity speed sensor (optional)
  • i200 AC carrier electronics (optional)
  • SAE 4340 alloy steel construction with satin nickel finish T260 and i200

Download printer

friendly version

The T261 rotary transformer coupled torque sensor was designed for in-line testing of motors, engines, transmissions, propellers, pumps, drivelines, and similar rotating devices. The T261 has greater stiffness, less rotating inertia, and smaller size than comparable models available from other suppliers. The T261 requires the use of AC carrier strain gage signal conditioning electronics such as SensorData’s i200. The optional zero velocity speed sensor is installed inside the T261 housing. Interconnecting cable assemblies are available as an option. SensorData will provide in-house calibration of the T261 with customersupplied electronics for a fee.

SPECIFICATIONS
(Subject to change without notice)
Rated Fatigue Capacity
5K, 10K, 20K lb-in
Rated Speed
10,000 rpm
Nonlinearity
0.05% of rated output
Hysteresis
0.05% of rated output
Nonrepeatability
0.02% of rated output
Rated Output, bridge, typical
2 mV/V
Zero Balance
+/-0.5% of rated output
Temperature Range, operating
-20 to +200 F
Temperature Range, compensated
+68 to +170 F
Temperature Effect on Output
0.001% of load/F
Temperature Effect on Zero
0.001% of rated output/F
Bridge Resistance, typical
350 ohms
Excitation
2.8 to 5 VAC rms, 3 kHz to 5 kHz
Insulation Resistance, bridge to case
>5000 megohms at 50 VDC
Input voltage, speed sensor, Vcc (optional) (1)
4.5 to 24 VDC
Maximum Load, safe (2)
200% of rated capacity
Maximum Load, ultimate (3)
400% of rated capacity
Number of Bridges
1
Weight
11.5 lb without i200, 12.5 lb with i200
Construction
SAE 4340 alloy steel with satin nickel finish
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage.

 

If the T261 is supplied with the optional SensorData i200 AC carrier strain gage conditioning electronics, the i200 instruction manual or data sheet should be referred to for wiring information and specifications.

 

ORDERING INFORMATION
T261-STD-Capacity Standard with receptacle and mating connector.
T261-STD-Capacity-A Same as T261-STD-Capacity except supplied with SensorData i200 strain gage conditioning electronics.
T261-STD-Capacity-S Same as T261-STD-Capacity except supplied with zero velocity speed sensor.
T261-STD-Capacity-S-A Same as T261-STD-Capacity except with zero velocity speed sensor & i200 strain gage conditioning electronics.
Foot Mount Option Replace STD with 105 in above model designations; e.g., T261-105-Capacity-S-A
Cable Assembly Optional; 10 ft., color coded, shielded, mating connector sensor end, customer specified connector instrument end.
Cable Assembly Optional; 10 ft., color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end.
Note Mounting hardware is optional and not included unless specified at time of order.
IMPORTANT NOTICE
Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer.

Download printerfriendly version

Back to Product Line Summary

Torque | Load Cell | Multiple Axis | Instrumentation

Entire contents copyright - all rights reserved -
 © 2004 by SensorData Technologies, Inc.