Back to Torque
High Capacity Flange Driven
Transformer Coupled Torque
Sensor Model T252, T254, T255
 |
- High stiffness and low inertia
- On-board shunt calibration circuit
- i200 AC carrier electronics (optional)
- Internal zero velocity speed sensor (optional)
- SAE 4340 alloy steel construction with satin nickel finish
|
Download printer

friendly version |
|
The T252, T254 and T255 high capacity rotary transformer coupled torque sensors were designed for inline testing of propellers, pumps, drivelines, and other devices where there is minimal axial space available for the torque sensor. The T252, T254 and T255 require the use of AC carrier strain gage signal conditioning electronics such as SensorData’s i200. The optional zero velocity speed sensor is installed inside the T252, T254 and T255 housing. Interconnecting cable assemblies are available as an option. SensorData will provide in-house calibration of the T252, T254 and T255 with customer-supplied electronics for a fee. |
SPECIFICATIONS
(Subject to change without notice) |
| Rated Fatigue Capacity |
50K, 100K, 200K, 500K, lb-in |
Rated Speed |
See table next page |
Nonlinearity
|
0.05% of rated output |
Hysteresis
|
0.05% of rated output |
Nonrepeatability
|
0.02% of rated output |
Rated Output, typical
|
2 mV/V |
Zero Balance
|
+/-0.5% of rated output |
Temperature Range, operating
|
-20 to +200 F |
Temperature Range, compensated
|
+68 to +170 F |
Temperature Effect on Output
|
0.001% of load/F |
Temperature Effect on Zero
|
0.001% of rated output/F |
Bridge Resistance, typical
|
350 ohms |
Excitation
|
2.8 to 5 VAC rms, 3 kHz to 5 kHz |
Insulation Resistance, bridge to case
|
>5000 megohms at 50 VDC |
Input voltage, speed sensor, Vcc (optional) (1)
|
4.5 to 24 VDC |
Maximum Load, safe (2)
|
200% of rated capacity |
Maximum Load, ultimate (3)
|
400% of rated capacity |
Number of Bridges
|
1 |
Weight
|
28 lb (T252), 41 lb ((T254), 65 lb (T255) |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1) Output is an open collector NPN with internal 4.7K ohm pull up resistor
(2) With load centered, maximum torque that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum torque that can be applied without physical damage. |

| T252, T254, and T255 if supplied with optional SensorData i200 AC carrier strain gage conditioning electronics, the i200 instruction manual or data sheet should be referred to for wiring information and specifications. |
|
ORDERING INFORMATION |
| T25X-STD-Capacity |
Standard with receptacle and mating connector. |
| T25X-STD-Capacity-A |
Same as T25X-STD-Capacity except supplied with SensorData i200 strain gage conditioning electronics. |
| T25X-STD-Capacity-S |
Same as T25X-STD-Capacity except supplied with zero velocity speed sensor. |
| T25X-STD-Capacity-S-A |
Same as T25X-STD-Capacity except with zero velocity speed sensor & i200 strain gage conditioning electronics. |
| Cable Assembly |
Optional; 10 ft., color coded, shielded, mating connector sensor end, customer specified connector instrument end. |
| Cable Assembly |
Optional; 10 ft., color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
| Note |
Mounting hardware is optional and not included unless specified at time of order. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -
© 2004 by SensorData Technologies, Inc. |