Back to Torque
Small Capacity Transformer
Coupled Shaft Torque Sensor
Model T231
 |
- 5 9/16” overall length including shafts
- 2 1/2” overall housing diameter
- Weighs 1.3 lbs.
- On-board shunt calibration circuit
- Zero velocity speed sensor (optional)
- SAE 4340 alloy steel construction with satin nickel finish
- Supplied with mating connector
|
Download printer

friendly version |
|
The T231 is designed for in-line testing of small motors, pumps, compressors, turbines, fans, and other fractional horsepower rated devices. The T231 rotary transformer requires the use of AC strain gage signal conditioning electronics such as SensorData’s i200. The T231 is supplied with a foot mount as standard. The optional zero velocity speed sensor is installed inside the T231 housing. Interconnecting cable assemblies are available as an option. SensorData will provide in-house calibration of the T231 with customer-supplied electronics for a fee. |
SPECIFICATIONS
(Subject to change without notice) |
| Rated Fatigue Capacity |
50, 100, 200, 500, 1K oz-in |
Rated Speed |
20,000 rpm |
Nonlinearity
|
0.05% of rated output |
Hysteresis
|
0.05% of rated output |
Nonrepeatability
|
0.02% of rated output |
Rated Output, typical
|
2 mV/V |
Zero Balance
|
+/-0.5% of rated output |
Temperature Range, operating
|
-20 to +220 F |
Temperature Range, compensated
|
+68 to +200 F |
Temperature Effect on Output
|
0.001% of load/F |
Temperature Effect on Zero
|
0.001% of rated output/F |
Bridge Resistance, typical
|
350 ohms |
Excitation
|
2.8 to 5 VAC rms, 3 kHz to 5 kHz |
Insulation Resistance, bridge to case
|
>5000 megohms at 50 VDC |
Input voltage, speed sensor, Vcc (optional) (1)
|
4.5 to 24 VDC |
Maximum Load, safe (2)
|
200% of rated capacity |
Maximum Load, ultimate (3)
|
400% of rated capacity |
Number of Bridges
|
1 |
Weight
|
1.3 lbs |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1) Output is an open collector NPN with internal 4.7K ohm pull up resistor.
(2) With load centered, maximum torque that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum torque that can be applied without physical damage. |

| If the T231 is supplied with the optional SensorData i200 AC carrier strain gage conditioning electronics, the i200 instruction manual or data sheet should be referred to for wiring information and specifications. |
|
ORDERING INFORMATION |
| T231-105-Capacity |
Standard with receptacle and mating connector. |
| T231-105-Capacity-A |
Same as T231-STD-Capacity except supplied with SensorData i200 strain gage conditioning electronics. |
| T231-105-Capacity-S |
Same as T231-105-Capacity except supplied with zero velocity speed sensor. |
| T231-105-Capacity-S-A |
Same as T231-105-Capacity except supplied with zero velocity speed sensor and i100 strain gage conditioning electronics. |
| Cable Assembly |
Optional; 10 ft., color coded, shielded, mating connector sensor end, customer specified connector instrument end. |
| Cable Assembly |
Optional; 10 ft., color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -