Back to Torque
Fatigue Rated Flange Coupled
Reaction Torque Sensor
T150, T153, T155, T156, T157
 |
- High torsional stiffness
- Fatigue rated
- 0.1% accuracy
- SAE 4340 Alloy Steel
- Supplied with mating connector
|
Download printer

friendly version |
|
SensorData’s T150 Series of fatigue rated flange coupled torque sensors is designed for use during life testing and “test-to-failure” of drive-line components and where there is a small degree of angular rotation or reciprocating motion involved. The T150 Series with inherent low-end measurement capability can be installed at the driver or absorber end of the measurement chain. Each flange face is provided with a pilot diameter to assist installation. AC carrier or DC strain gage signal conditioning electronics can be used with the T150 Series. Interconnecting cable assemblies are available as an option. In-house calibration of the T150 Series with SensorData’s electronics will be provided free of charge or with customer-supplied electronics for a fee. |
SPECIFICATIONS
(Subject to change without notice) |
| Rated Fatigue Capacity |
1K, 2K, 5K, 10K, 20K, 50K, 100K, 200K, 500K, 1000K lb-in |
Nonlinearity |
0.10% of rated output |
Hysteresis
|
0.10% of rated output |
Nonrepeatability
|
0.05% of rated output |
Rated Output, typical
|
2.00 mV/V |
Zero Balance
|
+/-1% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Bridge Resistance, typical
|
350 ohms |
Excitation Voltage, bridge, typical
|
10 VDC or VAC rms |
Excitation Voltage, bridge, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance, bridge to case
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% |
Maximum Load, ultimate (3)
|
300% |
Torsional Stiffness, typical
|
See table below |
Extraneous Loads, maximum
|
See table below |
Number of Bridges
|
1 |
Weight
|
Consult factory |
| Construction |
SAE 4340 Alloy Steel |
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |


|
ORDERING INFORMATION |
| T150-Capacity |
Standard; supplied with receptacle and mating connector. |
| T153-Capacity |
Standard; supplied with receptacle and mating connector. |
| T155-Capacity |
Standard; supplied with receptacle and mating connector. |
| T156-Capacity |
Standard; supplied with receptacle and mating connector. |
| T157-Capacity |
Standard; supplied with receptacle and mating connector. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -
© 2004 by SensorData Technologies, Inc. |