Back to Torque

Hollow Flange Reaction
Torque Sensor
Model T123

  • High torsional stiffness
  • 0.1% accuracy
  • AND 20002 & 10262 configured flanges
  • SAE 4340 Alloy Steel
  • Supplied with mating connector

Download printer

friendly version

The T123 is designed to support the housing of motors, generators, pumps, and similar devices and accurately measure the non-rotating reaction torque values where the rotating member of the device under test is passed through the center of the sensor. The T123 with inherent low-end measurement capability can be installed at the driver or absorber end of the measurement chain. The flanges, pilot diameters and bolting studs of the T123 are configured to AND standards. AC carrier or DC strain gage signal conditioning electronics can be used with the T123. A removable calibration arm and interconnecting cable assemblies are available as options. In-house calibration of the T123 with SensorData electronics will be provided free of charge or with customer-supplied electronics for a fee.

SPECIFICATIONS
(Subject to change without notice)
Rated Fatigue Capacity
50, 100, 200, 500, 1K, 2K, 5K lb-in
Nonlinearity
0.10% of rated output
Hysteresis
0.10% of rated output
Nonrepeatability
0.05% of rated output
Rated Output, typical
2.00 mV/V
Zero Balance
+/-1% of rated output
Temperature Range, operating
-65 to +200 F
Temperature Range, compensated
+70 to +170 F
Temperature Effect on Output
0.002% of load/F
Temperature Effect on Zero
0.002% of rated output/F
Bridge Resistance, typical
700 ohms
Excitation Voltage, bridge, typical
10 VDC or VAC rms
Excitation Voltage, bridge, maximum (1)
20 VDC or VAC rms
Insulation Resistance, bridge to case
>5000 megohms at 50 VDC
Maximum Load, safe (2)
150%
Maximum Load, ultimate (3)
300%
Torsional Stiffness, typical
See table below
Extraneous Loads, maximum
See table below
Number of Bridges
1
Weight
<14 lb
Construction
SAE 4340 Alloy Steel
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage.

 

ORDERING INFORMATION
T123-Capacity Standard; supplied with receptacle and mating connector.
Calibration arm Optional; length from center of sensor to end of calibration arm 10 inches.
Cable Assembly Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end.
Cable Assembly Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end.
IMPORTANT NOTICE
Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer.

Download printerfriendly version

Back to Product Line Summary

Torque | Load Cell | Multiple Axis | Instrumentation

Entire contents copyright - all rights reserved -