Back to Torque
Hollow Flange Reaction
Torque Sensor
Model T123
 |
- High torsional stiffness
- 0.1% accuracy
- AND 20002 & 10262 configured flanges
- SAE 4340 Alloy Steel
- Supplied with mating connector
|
Download printer

friendly version |
|
The T123 is designed to support the housing of motors, generators, pumps, and similar devices and accurately measure the non-rotating reaction torque values where the rotating member of the device under test is passed through the center of the sensor. The T123 with inherent low-end measurement capability can be installed at the driver or absorber end of the measurement chain. The flanges, pilot diameters and bolting studs of the T123 are configured to AND standards. AC carrier or DC strain gage signal conditioning electronics can be used with the T123. A removable calibration arm and interconnecting cable assemblies are available as options. In-house calibration of the T123 with SensorData electronics will be provided free of charge or with customer-supplied electronics for a fee. |
SPECIFICATIONS
(Subject to change without notice) |
| Rated Fatigue Capacity |
50, 100, 200, 500, 1K, 2K, 5K lb-in |
Nonlinearity |
0.10% of rated output |
Hysteresis
|
0.10% of rated output |
Nonrepeatability
|
0.05% of rated output |
Rated Output, typical
|
2.00 mV/V |
Zero Balance
|
+/-1% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Bridge Resistance, typical
|
700 ohms |
Excitation Voltage, bridge, typical
|
10 VDC or VAC rms |
Excitation Voltage, bridge, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance, bridge to case
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% |
Maximum Load, ultimate (3)
|
300% |
Torsional Stiffness, typical
|
See table below |
Extraneous Loads, maximum
|
See table below |
Number of Bridges
|
1 |
| Weight |
<14 lb |
| Construction |
SAE 4340 Alloy Steel |
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |


|
ORDERING INFORMATION |
| T123-Capacity |
Standard; supplied with receptacle and mating connector. |
| Calibration arm |
Optional; length from center of sensor to end of calibration arm 10 inches. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -
© 2004 by SensorData Technologies, Inc. |