Back to Torque
Small Capacity Reaction
Torque Sensor
Model T114
 |
- High torsional stiffness
- 0.1% accuracy
- 700 ohm bridge
- SAE 2024-T351 aluminum
- Supplied with mating connector
|
Download printer

friendly version |
|
The T114 is designed for measuring small values of torque found in miniature motors, pumps, compressors, turbines, fans, and other fractional horsepower rated devices, very small torque values associated with the measurement of viscosity, and losses caused by bearing friction. The T114 can be installed at either the driver or absorber end of the measurement chain and thus is able to measure the net available torque being delivered to the device under test. AC carrier or DC strain gage signal conditioning electronics can be used with the T114. Interconnecting cable assemblies are available as an option. In-house calibration of the T114 with SensorData electronics will be provided free of charge or with customer-supplied electronics for a fee.
|
SPECIFICATIONS
(Subject to change without notice) |
| Rated Fatigue Capacity |
50, 100, 200, 500, 1K oz-in |
Nonlinearity |
0.10% of rated output |
Hysteresis
|
0.10% of rated output |
Nonrepeatability
|
0.05% of rated output |
Rated Output, typical
|
2.00 mV/V |
Zero Balance
|
+/-1% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Bridge Resistance, typical
|
700 ohms |
Excitation Voltage, bridge, typical
|
10 VDC or VAC rms |
Excitation Voltage, bridge, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance, bridge to case
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% of rated capacity |
Maximum Load, ultimate (3)
|
300% of rated capacity |
Torsional Stiffness, typical
|
See table below |
Extraneous Loads, maximum
|
See table below |
Number of Bridges
|
1 (2 optional - consult factory) |
| Weight |
1.5 lbs |
| Construction |
SAE 2024-T351 Aluminum |
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered maximum torque that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered maximum torque that can be applied without physical damage. |


|
| ORDERING INFORMATION |
| T114-Capacity |
Standard; supplied with receptacle and mating connector. Mounting hardware not included. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -
© 2004 by SensorData Technologies, Inc. |