Back to Multiple Axis Sensors
Fully Fatigue Rated X-Y Force Sensor
Model M231
 |
- Measures X & Y forces
- 2 mV/V +/- 0.25% each axis
- Cross talk <0.5%
- Custom designs & capacities available
- SAE 4340 alloy steel construction with satin nickel finish
- Supplied with mating connectors
|
Download printer

friendly version |
|
SensorData’s M231 X-Y Force Sensor is primarily used to measure radial (R) and side (S) forces in tire test machines. The M231 sensor element was designed to ensure that force components would be evenly distributed over 360 degrees of tire rotation. Strain gage bridge wiring cancellation techniques provide a signal that is virtually error free. The M231 is the only force sensor of its type to be fatigue rated. The M231 is also available in sizes and capacities not covered by this data sheet. Consult the factory for details.
|
SPECIFICATIONS — X(R) & Y(S) Axis
(Subject to change without notice) |
| Rated Capacity |
See table below |
| Nonlinearity |
0.10% of rated output |
| Hysteresis |
0.10% of rated output |
Nonrepeatability
|
0.05% of rated output |
| Rated Output, typical |
2 mV/V +/- 0.25% |
| Zero Balance |
+/-1% of rated output |
| Temperature Range, operating |
-65 to +200 F |
| Temperature Range, compensated |
+70 to +170 F |
| Temperature Effect on Output |
0.002% of load/F |
| Temperature Effect on Zero |
0.002% of rated output/F |
| Input Impedance, minimum |
380 ohms |
| Output Impedance |
350 +/- 3.5 ohms |
| Excitation Voltage, typical |
10 VDC or VAC rms |
| Excitation Voltage, maximum (1) |
20 VDC or VAC rms |
| Insulation Resistance |
>5000 megohms at 50 VDC |
| Maximum Load, safe (2) |
150% of rated capacity |
| Maximum Load, ultimate (3) |
200% of rated capacity |
| Deflection at Rated Capacity, typical |
0.0025 in |
| Fatigue rating, full fatigue tension to full fatigue compression |
10  cycles |
| Number of Bridges |
2 |
| Weight, lb |
7.5 lb |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1) Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |


|
|
| M231-STD-X(R)/Y(S) |
Standard; include X(R) and Y(S) capacities from table above. Mating connectors supplied. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -