The F200 is a canister style load cell used for press calibration; material testing; tank, bin and hopper weighing; and rolling and reduction mill applications. The overall diameter is less than 2.5 inches, and the overall height is 3.5 inches. The F200 includes an integral hardened steel convex load button. The F200 can be used with AC carrier and DC strain gage signal conditioning electronics. Interconnecting cable assemblies are available as an option. SensorData will provide in-house calibration of the F200 with customer-supplied electronics for a fee.
|
SPECIFICATIONS
(Subject to change without notice) |
| Rated Capacity |
5K, 10K, 20K, 50K lbs |
Nonlinearity |
0.15% of rated output |
Hysteresis
|
0.10% of rated output |
Nonrepeatability
|
0.03% of rated output |
Rated Output, typical
|
2 mV/V |
Zero Balance
|
+/-2% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Input Impedance, minimum
|
380 ohms |
Output Impedance
|
350 +/-5 ohms |
Excitation Voltage, typical
|
10 VDC or VAC rms |
Excitation Voltage, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% of rated capacity |
Maximum Load, ultimate (3)
|
300% of rated capacity |
Deflection at Rated Capacity, typical
|
0.002 in |
Number of Bridges
|
1 |
Weight
|
2 lb |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1) Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |
|
ORDERING INFORMATION |
| F200-STD-Capacity |
Standard, capacity 5K, 10K, 20K, 50K lb, and supplied with PT02E-10-6P receptacle and mating connector. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
|