Back to Load Cells
Fatigue Rated Hydraulic
Actuator Load Cell
Model F643
|
- Tension & compression operation
- 4.25” overall height & 1.5” overall diameter
- 3/4-16 UNF-2A & 3/4-16 UNF-2B threads
- SAE 4340 alloy steel construction with satin nickel finish
- Supplied with mating connector
|
Download printer

friendly version |
|
The F643 is fully fatigue rated and designed to measure in-line axial loads. Its sensing element has proved, in actual tests, to be highly resistant to the effects of bending and off-center loading. The F643 is mechanically interchangeable with competitors’ products and is compatible with AC carrier and DC strain gage signal conditioning electronics. Interconnecting cable assemblies are available as an option. SensorData will provide in-house calibration of the F643 with customer-supplied electronics for a fee.
|
SPECIFICATIONS
(Subject to change without notice) |
Rated Capacity |
500, 1K, 2K, 3K, 5K lbs |
Nonlinearly |
0.25% of rated output |
Hysteresis
|
0.15% of rated output |
Nonrepeatability
|
0.05% of rated output |
Rated Output, typical
|
2 mV/V (500 lb, 1 mV/V) |
Zero Balance
|
+/-1% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Input Impedance, minimum
|
380 ohms |
Output Impedance
|
350 +/-3.5 ohms |
Excitation Voltage, typical
|
10 VDC or VAC rms |
Excitation Voltage, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% of rated capacity |
Maximum Load, ultimate (3)
|
300% of rated capacity |
Deflection at Rated Capacity, typical
|
0.002 in |
Fatigue Rating, full
|
fatigue tension to full fatigue compression
10  cycles |
| Number of Bridges |
1 |
| Weight |
1.2 lbs |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |


|
ORDERING INFORMATION |
| F643-107-Capacity |
Standard supplied with PT02E-8-4P receptacle and mating connector. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
Download printer friendly version
|
Back to Product Line Summary
Torque | Load Cell | Multiple Axis | Instrumentation
Entire contents copyright - all rights reserved -
© 2004 by SensorData Technologies, Inc
|