Back to Load Cells
Fatigue Rated Load Cell
Model F370
 |
- Fully fatigue rated
- Tension & compression operation
- 3” overall length
- 1.5” overall diameter
- 1/2-20 UNF-2B threads
- SAE 4340 alloy steel construction with satin nickel finish
- Supplied with mating connector
|
Download printer

friendly version |
|
The F370 is fully fatigue rated and is a practical replacement for pancake load cells, S beams, and canister load cells. The F370 was designed for use with lever arm and rod end bearing combinations to measure CW and CCW torque, with hydraulic actuators, and wherever tension and compression force measurements are made. The F370 is compatible with AC Carrier and DC strain gage signal conditioning electronics.
|
SPECIFICATIONS
(Subject to change without notice) |
Rated Capacity |
500, 1K, 2K, 3K, 5K lbs |
Nonlinearity
|
0.25% of rated output |
Hysteresis
|
0.15% of rated output |
Nonrepeatability
|
0.05% of rated output |
Rated Output, typical
|
2 mV/V |
Zero Balance
|
+/-1% of rated output |
Temperature Range, operating
|
-65 to +200 F |
Temperature Range, compensated
|
+70 to +170 F |
Temperature Effect on Output
|
0.002% of load/F |
Temperature Effect on Zero
|
0.002% of rated output/F |
Input Impedance, minimum
|
380 ohms |
Output Impedance
|
350 +/- 3.5 ohms |
Excitation Voltage, typical
|
10 VDC or VAC rms |
Excitation Voltage, maximum (1)
|
20 VDC or VAC rms |
Insulation Resistance
|
>5000 megohms at 50 VDC |
Maximum Load, safe (2)
|
150% of rated capacity |
Maximum Load, ultimate (3)
|
300% of rated capacity |
Deflection at Rated Capacity, typical
|
0.002 in |
Fatigue rating, full
|
fatigue tension to full fatigue compression 10  cycles |
| Number of Bridges |
1 |
| Weight, lbs |
1.2 |
| Construction |
SAE 4340 alloy steel with satin nickel finish |
(1)Temperature gradients caused by higher excitation voltages may effect performance.
(2) With load centered, maximum load that can be applied without producing a permanent shift in performance characteristics.
(3) With load centered, maximum load that can be applied without physical damage. |

|
ORDERING INFORMATION |
| F370-107-Capacity |
Standard supplied with PT02E-8-4P receptacle and mating connector. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, customer supplied connector instrument end. |
| Cable Assembly |
Optional; 10 ft, color coded, shielded, mating connector sensor end, leads stripped and tinned instrument end. |
IMPORTANT NOTICE |
| Dimensions above are in inches unless otherwise noted. Manufacturer not responsible for any modification to product, fixtures, or accessories made by user or third party. User should request certified drawings before designing mountings or fixtures. Manufacturer reserves right to modify or change design, dimensions, specifications, and features of this product without prior written notice. Changes to NOTICE must be in writing and accepted by manufacturer. |
|
|